ModemManager.GdbusModemFirmware¶
- Implementations:
ModemManager.GdbusModemFirmwareProxy
,ModemManager.GdbusModemFirmwareSkeleton
Methods¶
class |
|
class |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Virtual Methods¶
|
|
|
Properties¶
Name |
Type |
Flags |
Short Description |
---|---|---|---|
r/w |
UpdateSettings |
Signals¶
Name |
Short Description |
---|---|
Signal emitted when a remote caller is invoking the ‘List() [gdbus-method-org-freedesktop-ModemManager1-Modem-Firmware.List]’ D-Bus method. |
|
Signal emitted when a remote caller is invoking the ‘Select() [gdbus-method-org-freedesktop-ModemManager1-Modem-Firmware.Select]’ D-Bus method. |
Fields¶
None
Class Details¶
- class ModemManager.GdbusModemFirmware¶
- Bases:
- Structure:
Abstract interface type for the D-Bus interface ‘org.freedesktop.ModemManager1.Modem.Firmware [gdbus-interface-org-freedesktop-ModemManager1-Modem-Firmware.top_of_page]’.
- classmethod interface_info()¶
- Returns:
A
Gio.DBusInterfaceInfo
. Do not free.- Return type:
Gets a machine-readable description of the ‘org.freedesktop.ModemManager1.Modem.Firmware [gdbus-interface-org-freedesktop-ModemManager1-Modem-Firmware.top_of_page]’ D-Bus interface.
- classmethod override_properties(klass, property_id_begin)¶
- Parameters:
klass (
GObject.ObjectClass
) – The class structure for aGObject.Object
derived class.property_id_begin (
int
) – The property id to assign to the first overridden property.
- Returns:
The last property id.
- Return type:
Overrides all
GObject.Object
properties in theModemManager.GdbusModemFirmware
interface for a concrete class. The properties are overridden in the order they are defined.
- call_list(cancellable, callback, *user_data)¶
- Parameters:
cancellable (
Gio.Cancellable
orNone
) – AGio.Cancellable
orNone
.callback (
Gio.AsyncReadyCallback
orNone
) – AGio.AsyncReadyCallback
to call when the request is satisfied orNone
.
Asynchronously invokes the ‘List() [gdbus-method-org-freedesktop-ModemManager1-Modem-Firmware.List]’ D-Bus method on self. When the operation is finished, callback will be invoked in the thread-default main loop of the thread you are calling this method from (see
GLib.MainContext.push_thread_default
()). You can then callModemManager.GdbusModemFirmware.call_list_finish
() to get the result of the operation.See
ModemManager.GdbusModemFirmware.call_list_sync
() for the synchronous, blocking version of this method.
- call_list_finish(res)¶
- Parameters:
res (
Gio.AsyncResult
) – TheGio.AsyncResult
obtained from theGio.AsyncReadyCallback
passed toModemManager.GdbusModemFirmware.call_list
().- Raises:
- Returns:
- Return type:
(
bool
, out_selected:str
, out_installed:GLib.Variant
)
Finishes an operation started with
ModemManager.GdbusModemFirmware.call_list
().
- call_list_sync(cancellable)¶
- Parameters:
cancellable (
Gio.Cancellable
orNone
) – AGio.Cancellable
orNone
.- Raises:
- Returns:
- Return type:
(
bool
, out_selected:str
, out_installed:GLib.Variant
)
Synchronously invokes the ‘List() [gdbus-method-org-freedesktop-ModemManager1-Modem-Firmware.List]’ D-Bus method on self. The calling thread is blocked until a reply is received.
See
ModemManager.GdbusModemFirmware.call_list
() for the asynchronous version of this method.
- call_select(arg_uniqueid, cancellable, callback, *user_data)¶
- Parameters:
arg_uniqueid (
str
) – Argument to pass with the method invocation.cancellable (
Gio.Cancellable
orNone
) – AGio.Cancellable
orNone
.callback (
Gio.AsyncReadyCallback
orNone
) – AGio.AsyncReadyCallback
to call when the request is satisfied orNone
.
Asynchronously invokes the ‘Select() [gdbus-method-org-freedesktop-ModemManager1-Modem-Firmware.Select]’ D-Bus method on self. When the operation is finished, callback will be invoked in the thread-default main loop of the thread you are calling this method from (see
GLib.MainContext.push_thread_default
()). You can then callModemManager.GdbusModemFirmware.call_select_finish
() to get the result of the operation.See
ModemManager.GdbusModemFirmware.call_select_sync
() for the synchronous, blocking version of this method.
- call_select_finish(res)¶
- Parameters:
res (
Gio.AsyncResult
) – TheGio.AsyncResult
obtained from theGio.AsyncReadyCallback
passed toModemManager.GdbusModemFirmware.call_select
().- Raises:
- Returns:
- Return type:
Finishes an operation started with
ModemManager.GdbusModemFirmware.call_select
().
- call_select_sync(arg_uniqueid, cancellable)¶
- Parameters:
arg_uniqueid (
str
) – Argument to pass with the method invocation.cancellable (
Gio.Cancellable
orNone
) – AGio.Cancellable
orNone
.
- Raises:
- Returns:
- Return type:
Synchronously invokes the ‘Select() [gdbus-method-org-freedesktop-ModemManager1-Modem-Firmware.Select]’ D-Bus method on self. The calling thread is blocked until a reply is received.
See
ModemManager.GdbusModemFirmware.call_select
() for the asynchronous version of this method.
- complete_list(invocation, selected, installed)¶
- Parameters:
invocation (
Gio.DBusMethodInvocation
) – AGio.DBusMethodInvocation
.selected (
str
) – Parameter to return.installed (
GLib.Variant
) – Parameter to return.
Helper function used in service implementations to finish handling invocations of the ‘List() [gdbus-method-org-freedesktop-ModemManager1-Modem-Firmware.List]’ D-Bus method. If you instead want to finish handling an invocation by returning an error, use g_dbus_method_invocation_return_error() or similar.
This method will free invocation, you cannot use it afterwards.
- complete_select(invocation)¶
- Parameters:
invocation (
Gio.DBusMethodInvocation
) – AGio.DBusMethodInvocation
.
Helper function used in service implementations to finish handling invocations of the ‘Select() [gdbus-method-org-freedesktop-ModemManager1-Modem-Firmware.Select]’ D-Bus method. If you instead want to finish handling an invocation by returning an error, use g_dbus_method_invocation_return_error() or similar.
This method will free invocation, you cannot use it afterwards.
- do_handle_list(invocation) virtual¶
- Parameters:
invocation (
Gio.DBusMethodInvocation
) –- Return type:
- do_handle_select(invocation, arg_uniqueid) virtual¶
- Parameters:
invocation (
Gio.DBusMethodInvocation
) –arg_uniqueid (
str
) –
- Return type:
Signal Details¶
- ModemManager.GdbusModemFirmware.signals.handle_list(gdbus_modem_firmware, invocation)¶
- Signal Name:
handle-list
- Flags:
- Parameters:
gdbus_modem_firmware (
ModemManager.GdbusModemFirmware
) – The object which received the signalinvocation (
Gio.DBusMethodInvocation
) – AGio.DBusMethodInvocation
.
- Returns:
Gio.DBUS_METHOD_INVOCATION_HANDLED
orTrue
if the invocation was handled,Gio.DBUS_METHOD_INVOCATION_UNHANDLED
orFalse
to let other signal handlers run.- Return type:
Signal emitted when a remote caller is invoking the ‘List() [gdbus-method-org-freedesktop-ModemManager1-Modem-Firmware.List]’ D-Bus method.
If a signal handler returns
True
, it means the signal handler will handle the invocation (e.g. take a reference to invocation and eventually callModemManager.GdbusModemFirmware.complete_list
() or e.g. g_dbus_method_invocation_return_error() on it) and no other signal handlers will run. If no signal handler handles the invocation, theGio.DBusError.UNKNOWN_METHOD
error is returned.
- ModemManager.GdbusModemFirmware.signals.handle_select(gdbus_modem_firmware, invocation, arg_uniqueid)¶
- Signal Name:
handle-select
- Flags:
- Parameters:
gdbus_modem_firmware (
ModemManager.GdbusModemFirmware
) – The object which received the signalinvocation (
Gio.DBusMethodInvocation
) – AGio.DBusMethodInvocation
.arg_uniqueid (
str
) – Argument passed by remote caller.
- Returns:
Gio.DBUS_METHOD_INVOCATION_HANDLED
orTrue
if the invocation was handled,Gio.DBUS_METHOD_INVOCATION_UNHANDLED
orFalse
to let other signal handlers run.- Return type:
Signal emitted when a remote caller is invoking the ‘Select() [gdbus-method-org-freedesktop-ModemManager1-Modem-Firmware.Select]’ D-Bus method.
If a signal handler returns
True
, it means the signal handler will handle the invocation (e.g. take a reference to invocation and eventually callModemManager.GdbusModemFirmware.complete_select
() or e.g. g_dbus_method_invocation_return_error() on it) and no other signal handlers will run. If no signal handler handles the invocation, theGio.DBusError.UNKNOWN_METHOD
error is returned.
Property Details¶
- ModemManager.GdbusModemFirmware.props.update_settings¶
- Name:
update-settings
- Type:
- Default Value:
- Flags:
Represents the D-Bus property ‘“UpdateSettings” [gdbus-property-org-freedesktop-ModemManager1-Modem-Firmware.UpdateSettings]’.
Since the D-Bus property for this
GObject.Object
property is readable but not writable, it is meaningful to read from it on both the client- and service-side. It is only meaningful, however, to write to it on the service-side.